<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-08 08-04-22
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 44 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
5 kHz 49 kHz 18730 0,1815
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,6 dBr -0,46 dBr 0,6 dBr 5,2
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 8:04, 8.12.2025
RT
"Cesky rozhlas Plus - politika-spolecnost-byznys-veda "
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 49 kHz MIN: 5 kHz % above 77 kHz: 0,1815 Acquired: 2025/12/08 8:04:19 Total samples: 18730 Equivalent time: 0:15:36 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: 0,6 dBr MIN: -1,6 dBr AVE: -0,46 dBr % above 0,2 dBr: 5,2 Last value: 0,1 dBr (2025/12/08 8:04:19) 07:50 07:52 07:54 07:56 07:58 08:00 08:02 08:04 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality